To remove the drain pump:
1
Unplug ice maker from the electrical supply and remove the rear access cover from the
icemaker.
2
Unscrew the leveling leg in the back corner until the end of the threaded portion is flush
with the threaded nut insert in the base (A).
3
Unscrew the 4 hose clamps and remove the 3 hoses from the front of the drain pump (B).
4
Rotate the drain pump and remove from the ice maker (C). It may be necessary to
disconnect the ground wire connection in the back flange of the cabinet (D).
5
Disconnect the ice maker power cord from the drain pump (E).
6
To drain water from the pump refer to ‘Preparing the ice maker for storage’.
Installation of drain pump is reverse of this procedure.