Seitenansicht 12
CABINET PREPARATION
12
0 Clearance
B
A
F
C
H
E
D
G
0 Clearance
C
J
I
36" Min. to
Combustibles
12" Min. to
Combustibles
without backguard
Min. 30" Wide Hood
CAUTION:
36" Min. to
combustible
material ,
from cooking
surface
35-3/8" Max. For Level Counter,
36-3/4" Max. With Range
Leveling Legs Fully Extended
12" Min. to combustible
material , each side
cooking surface
13"
Max.
18" Min.
As defined in the
National Fuel Gas Code
(ANSI Z223.1, Latest Edition).
The range height is adjustable. The level of the
range top must be at the same level or above the countertop level.
Electrical and
Gas Supply
4"
16 "
2 "
Fig. 10 RGS 305 Models Only
Fig. 11 RGS 305 Models Only
A B C D E F G H I J WIDTH
RGS 305 Models 28-1/8 10-1/8 2 35-1/2min. 37max. 30 44 27-1/2 1-5/16 24-1/4 26-3/4 29-7/8